oms_sync_delay

2025-10-09 03:34:24  Updated

Impact on the system

This alert affects the real-time performance of data synchronization. If this alert is left unhandled for a long time, the data synchronization task cannot be recovered.

Possible causes

  • The source and target databases are not properly configured.

  • Privileges are not properly assigned.

  • The network is disconnected.

  • Other special circumstances have occurred.

Solution

Go to the details page of the data synchronization task, and click View Component Monitoring in the upper-right corner to view the timestamp information of the Store and Connector components.

Monitoring

  • If the Store component has a large delay, check its logs to check whether an error or exception has occurred.

  • If the checkpoint of the Store component is basically in real time but the Connector component has a large delay, check the logs of the Connector component to check whether an error or exception has occurred.

  • If no specific error message is found, feed back the phenomenon and component logs to technical support engineers of OMS.

Contact Us