The following table describes ODP parameters that take effect only after a restart.

Parameter Default value Value range Note
stack_size 1 MB [1MB,10MB] The size of the thread stack. This parameter is used for thread creation.
work_thread_num 128 [1,128] The number of worker threads. This parameter is used for worker thread initialization.
task_thread_num 2 [1,4] The number of threads for tasks. This parameter is used for task thread initialization.
block_thread_num 1 [1,4] The number of threads for blocking tasks. This parameter is used for thread initialization.
grpc_thread_num 8 [8,16] The number of gRPC threads.
grpc_client_num 9 [9,16] The number of gRPC clients.
automatic_match_work_thread true / Specifies whether to automatically create worker threads based on the number of CPU cores. If you set the parameter to true, the maximum number of worker threads is determined by the work_thread_num parameter.
enable_strict_kernel_release true / Specifies whether the OS kernel must be verified.
net_accept_threads 2 [0,8] The number of threads that run accept tasks.
frequent_accept true / Specifies whether to initialize the net accept parameter.
enable_cpu_topology false / Specifies whether to enable CPU affinity.
enable_compression_protocol true / Specifies whether to enable the compression protocol.